
DATA CENTER SOLUTION
From Infrastructure, Power Cord, Access Management & Thermal Management, Aqua-Terra offers a wide range of solution to our Data Center Customer.

Molded Power Cords
Custom Made in the USA
Bus and Electrical Drops
Safely power your data cabinet or industrial equipment


Colors & Length:

USA Molds
C14 Straight: 18, 16, 14 AWG
C14 Right: 18, 16, 14 AWG
C14 Left: 18, 16, 14 AWG
C19 Straight: 16, 14, 12 AWG
C19 Right: 16, 14, 12 AWG
C19 Left: 16, 14, 12 AWG
C20 Straight: 16, 14, 12 AWG
C20 Right: 16, 14, 12 AWG
C20 Left: 16, 14, 12 AWG
C5 Straight: 18 AWG
C5 Right: 18 AWG
C5 Left: 18 AWG
C13 Straight: 18, 16, 14 AWG
C13 Right: 18, 16, 14 AWG
C13 Left: 18, 16, 14 AWG
C15 Straight: 18, 16, 14 AWG
C15 Right: 18, 16, 14 AWG
C15 Left: 18, 16, 14 AWG
5-15 Straight: 18, 16, 14 AWG
5-20 Straight: 16, 14, 12 AWG
L5-20 Straight: 18, 16, 14, 12 AWG
6-15 Straight: 18, 16, 14, 12 AWG
6-20 Straight: 18, 16, 14, 12 AWG
L6-20 Straight: 18, 16, 14, 12 AWG
Above molds can be applied to over 4,000 different cords in-stock.
Bus Drop

NEMA Twist Lock
Strain Relief

Box wire grip
Electrical Drop

Mounting Options
Termination

Ultrasonic Weld

Russellstoll®

Bus drop grip

NEMA Duplex

Ferrules
IEC60309 Pin & Sleeve
to connect Data Center or Industrial Equipment

Hubbell / ABB / PCE / Mennekes:

[3 Wire]
100-130 Volt 4h clock position Yellow 220-250 Volt 6h clock position Blue 480 Volt 7h clock position Red
550 Volt DC 8h clock position Black

[4 Wire]
125/250 Volt 12h clock position Orange 200-250 Volt 9h clock position Blue 380-415 Volt 6h clock position Red
480 Volt 7h clock position Red 600 Volt 5h clock position Black

[5 Wire]
120/208 Volt 9h clock position Blue 240/415 Volt 6h clock position Red 277/480 Volt 7h clock position Red 400 Volt DC 8h clock position Red 347/600 Volt 5h clock position Black

Amperages Available
16A, 20A, 30A, 32A, 60A, 63A, 100A, 125A
Online Custom Configuration
-
Design, price and place orders in Real-Time
-
Single ended power supply or device cords
-
Extension cords using SJTOW, SOOW or Type W cord jackets
-
Plug adapter pigtails between IEC60309, NEMA, and Non-NEMA standards
-
Plug, connector, receptacle, inlet and back box electrical parts to complete your installation
Country Power Cords


PDU Cable Whips
to safely power your Data Cabinet


Receptacle / Connector / Wire:
-
NEMA Twist Lock
-
Russellstoll
-
NEMA Straight Blade
-
Isolated Ground
-
IEC 60309 Pin & Sleeve
-
Hubbell (Non-NEMA)
-
IEC 60309 Receptacle
-
CA STD 50A Locking
UL Components:
-
Hubbell
-
KafTech / Anaconda
-
Russellstoll
-
Thomas & Betts
-
Raco Bell
-
ABB
Options:
-
Stranded or Solid THHN
-
Custom Labelling
-
Multiple Circuits per Conduit
-
Receptacles Inline
-
Packaging Choices
-
Multiple Nippled Boxes
-
Box Mounting Hardware
-
Staggered Boxes
-
Strain Relief Grips
-
Zero Halogen
Conduit Stock Colors:

Custom Assembled
Indoor and Outdoor Power Cords




Length Tolerance: 1 -100 feet


Cord Types: SJT, SJTOW, STO, STOW, SOOW
Secure Sleeves
to ensure cords stay connected


Plug Options: Male

Connector Options: Female

Locking Cords
Z-LOCK
The Z-Lock universally compatible locking power cord locks into place on both sides, regardless of the brand of IT hardware or the manufacturer of PDU / plug strip.

W-LOCK
Use with any APC AP8000 series rack PDU to secure the C14 or C20 end to the power source. Secures the C13 or C19 female ends via an integrated spring loaded grip.

P-LOCK
Use with any ServerTech Lockable CDU, Raritan SecureLock PDU, or Emerson Knurr PDU to secure the C14 or C20 end to the power source.

IEC-LOCK
Use with Geist PDU Strips that have been configured with IEC Lock proprietary outlets to secure the C14 or C20 end. Secures the C13 or C19 female ends with a spring loaded grip.

V-LOCK
Use with any APC AP8000 series rack PDU to secure the C14 or C20 end to the power source. To lock the C13 or C19 connectors the inlets must have the corresponding V-Lock.
